INPHASE

Dr. InPhase Edu Series – How to use Krykard ALM-32/33/35 to carry out Power Quality Study

Power Quality Study Using Krykard ALM-35 is an essential process for identifying electrical system issues such as harmonic distortion, poor power factor, voltage imbalance, voltage fluctuations, and excessive current loading. In modern industrial facilities, maintaining good power quality is critical for ensuring equipment reliability, energy efficiency, and compliance with IEEE 519 standards.

A properly executed Power Quality Study Using Krykard ALM-35 helps engineers identify hidden electrical problems before they impact productivity, equipment reliability, and energy efficiency.

The Krykard ALM-32, ALM-33, and ALM-35 Portable Power Quality Analyzers are powerful diagnostic tools that help engineers evaluate electrical system performance and identify the root causes of power quality problems. In this edition of the Dr. InPhase Edu Series, we explain the step-by-step procedure for conducting a comprehensive power quality study using these analyzers.

Power Quality Study Using Krykard ALM-35 analyzer setup

What is a Power Quality Study?

A power quality study involves monitoring and analyzing electrical parameters over a specified period to assess the health of an electrical distribution system. The study helps identify issues that may affect productivity, equipment life, and energy consumption.

Objectives of a Power Quality Study Using Krykard ALM-35

A typical power quality study aims to:

  • Measure voltage and current parameters

  • Analyze harmonic distortion levels

  • Evaluate power factor performance

  • Identify voltage sags and swells

  • Detect load imbalances

  • Assess transformer and cable loading

  • Verify IEEE 519 compliance

  • Recommend corrective actions

Why Use Krykard ALM-32/33/35 for Power Quality Studies?

The Krykard ALM series provides comprehensive power quality monitoring capabilities suitable for industrial and commercial applications.

The accuracy and portability of the analyzer make Power Quality Study Using Krykard ALM-35 a preferred approach for industrial audits and troubleshooting projects.

Key Features of Krykard ALM-32/33/35

  • True RMS measurements

  • Harmonic analysis up to high-order harmonics

  • Real-time waveform capture

  • Voltage sag and swell recording

  • Power factor monitoring

  • Energy consumption analysis

  • Data logging and report generation

  • Three-phase system monitoring

These capabilities make the analyzers ideal for troubleshooting power quality issues and planning harmonic mitigation solutions.

Step 1: Identify the Monitoring Location

Before connecting the analyzer, determine the most appropriate monitoring point.

Recommended Measurement Locations

  • Main LT Panel

  • PCC (Point of Common Coupling)

  • Transformer Secondary Side

  • Critical Load Panels

  • VFD Panels

  • Data Center Distribution Panels

Selecting the correct location ensures accurate identification of power quality issues.

Step 2: Connect Voltage Leads Safely

The next step in a Power Quality Study Using Krykard ALM-35 is connecting the voltage measurement leads.

Verify:

  • Correct phase sequence

  • Secure connections

  • Proper voltage ratings

  • Grounding integrity

Always follow plant safety procedures and lockout-tagout requirements where applicable.

Step 3: Install Current Transformers (CTs)

Proper CT installation is critical for accurate current measurements.

Best Practices for CT Installation

  • Verify CT orientation

  • Match phase identification correctly

  • Ensure secure placement

  • Confirm current rating compatibility

  • Avoid loose connections

Incorrect CT installation can result in inaccurate power quality data.

Step 4: Configure Analyzer Settings

After wiring is complete, configure the analyzer according to the system being monitored.

Typical settings include:

  • System voltage

  • Frequency (50 Hz or 60 Hz)

  • CT ratio

  • PT ratio (if applicable)

  • Logging interval

  • Recording duration

Accurate settings are essential for obtaining meaningful study results.

Step 5: Start Data Logging

Begin recording data for a suitable monitoring period.

Recommended Study Duration

  • 24 Hours – Basic Assessment

  • 72 Hours – Industrial Analysis

  • 7 Days – Comprehensive Power Quality Study

  • 30 Days – Utility and Critical Facility Monitoring

Longer monitoring periods provide a more accurate representation of system behavior.

Step 6: Analyze Harmonic Distortion

One of the most important aspects of a Power Quality Study Using Krykard ALM-35 is harmonic analysis.

Parameters to Review

  • Voltage THD

  • Current THD

  • Individual Harmonics

  • 5th Harmonic

  • 7th Harmonic

  • 11th Harmonic

  • 13th Harmonic

High harmonic levels often indicate the presence of non-linear loads such as VFDs, UPS systems, rectifiers, and LED lighting.

Step 7: Evaluate Power Factor Performance

Poor power factor increases electrical losses and utility penalties.

Review:

  • Displacement Power Factor

  • True Power Factor

  • Reactive Power Demand

  • Leading/Lagging Conditions

This analysis helps determine whether capacitor banks, SVGs, or power factor correction systems are required.

Step 8: Review Voltage Events

Voltage disturbances can affect sensitive equipment and production processes.

Critical Voltage Events

  • Voltage Sags

  • Voltage Swells

  • Short Interruptions

  • Flicker Events

  • Transients

The Krykard ALM analyzers automatically capture these events for detailed analysis.

Step 9: Generate and Interpret the Report

The final stage of the Power Quality Study Using Krykard ALM-35 is report generation and interpretation.

A comprehensive report should include:

  • Single Line Diagram

  • Measurement Location Details

  • Harmonic Analysis Results

  • Power Factor Analysis

  • Voltage Event Summary

  • Transformer Loading Assessment

  • IEEE 519 Compliance Evaluation

  • Recommended Corrective Actions

Common Findings During Power Quality Studies

Industrial facilities frequently encounter:

  • Excessive harmonic distortion

  • Capacitor bank failures

  • Transformer overheating

  • Poor power factor

  • Neutral current overloading

  • Voltage imbalance

  • Frequent voltage sags

  • High energy losses

Identifying these issues early helps prevent costly downtime and equipment failures.

Recommended Solutions After a Power Quality Study

Based on study findings, corrective measures may include:

Active Harmonic Filters (AHF)

AHFs dynamically eliminate harmonic currents and help maintain IEEE 519 compliance.

Static VAR Generators (SVG)

SVGs provide dynamic reactive power compensation and improve power factor.

Hybrid Harmonic Filters

Hybrid solutions combine passive and active technologies for effective harmonic mitigation.

Power Quality Monitoring Systems

Continuous monitoring helps maintain long-term system performance.

Why InPhase Recommends Detailed Power Quality Studies

At InPhase Power Technologies, every successful harmonic mitigation project begins with a detailed power quality assessment. Our engineers use advanced analyzers and industry best practices to identify root causes and recommend the most effective solutions.

A professional power quality study enables facilities to:

  • Improve energy efficiency

  • Reduce downtime

  • Protect critical equipment

  • Achieve IEEE 519 compliance

  • Optimize electrical system performance

During a Power Quality Study Using Krykard ALM-35, engineers can accurately identify dominant harmonic orders and determine whether harmonic mitigation solutions are required.

 

A Power Quality Study Using Krykard ALM-35 provides valuable insights into the health and performance of industrial electrical systems. By following a structured approach using Krykard ALM-32, ALM-33, or ALM-35 analyzers, engineers can identify harmonic issues, power factor problems, voltage disturbances, and system inefficiencies.

The results of a well-executed power quality study form the foundation for implementing effective solutions such as Active Harmonic Filters, Static VAR Generators, and other advanced power quality technologies. Regular power quality assessments help industries improve reliability, reduce operating costs, and maintain compliance with IEEE 519 standards.

Scroll to Top

VAJRA - Catalogue

You will receive our VAJRA product catalogue on your mail id

=

SHAF - Catalogue

You will receive our SHAF product catalogue on your mail id

=

SVG - Catalogue

You will receive our SVG product catalogue on your mail id

=

AHF - Catalogue

You will receive our AHF product catalogue on your mail id

=

Modular SVG - Catalogue

You will receive our modular SVG product catalogue on your mail id

=

Modular AHF - Catalogue

You will receive our modular AHF product catalogue on your mail id

=